Stage 1 Drilling at Fiery Creek Confirms Large-scale CU-AG S
Released
Released
Announcement PDF
ASX RELEASE | ASX:EMU
23 March 2026
P a g e | 1
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
STAGE1DRILLINGATFIERYCREEKCONFIRMSLARGE-SCALECU–AG
SYSTEMANDREFINESYATAGAVALLEYTARGETS
HIGHLIGHTS
Stage 1 drilling at Fiery Creek successfully validates EMU’s geological and structural models,
with mineralisation confirmed as steep shear-hosted Cu–Ag system with associated flat-lying
intrusive-related zones.
Drilling identifies multiple steeply-dipping mineralised “branches” linked to a central feeder
structure.
Drilling intercepts include the following, noting that the Fiery Creek targets remain open along
strike and at depth:
- YFC002 – 13 m @ 0.5% Cu and 9.7 g/t Ag from 49 m, confirming Ag association; including
1 m @ 1.29% Cu and 26.9 g/t Ag from 50 m.
- YFC004 – 3 m @ 0.60% Cu and 13.3 g/t Ag from 40 m; including 1 m @ 1.5% Cu and 31.3
g/t Ag from 41 m.
- YFC003 – 13 m @ 0.25% Cu and 5.3 g/t Ag from 37 m; including 1 m @ 0.49% Cu and
12.5 g/t Ag from 37 m and 1 m @ 0.65% Cu and 7.3 g/t Ag from 43 m.
- YFC001 – 1 m @ 1.02% Cu and 23 g/t Ag from 48 m.
- YFC006 – 1 m @ 1.00% Cu and 28 g/t Ag from 40 m.
Drilling and assay results received to date have refined geological and structural
interpretations, with the system now interpreted as a multi-phase porphyry-related intrusive
complex rather than simple structurally hosted vein targets.
The results of the Fiery Creek drilling have significantly enhanced the company’s confidence
in targeting for the upcoming 2026 Yataga Valley drilling programme.
EXECUTIVE SUMMARY
The Stage 1 drilling programme at Fiery Creek has delivered a strong technical outcome, confirming
EMU’s conceptual model of a structurally controlled Cu–Ag mineralised system associated with a
fertile intrusive complex (Figure 1).
While grades encountered are variable (see Table 1 and 2), the programme has successfully
identified the geometry, controls and potential scale of mineralisation, providing a clear framework
for follow-up drilling and materially improving confidence in targeting across the broader Yataga
Project.
ASX RELEASE | ASX:EMU
P a g e | 2
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Importantly, the results confirm that Fiery Creek represents part of a larger, mineralised intrusive
system, with direct implications for the higher-priority Yataga Valley targets.
Figure 1: Yataga intrusive Complex Showing both Fiery Creek and Yataga Valley Prospects
DRILLING RESULTS AND GEOLOGICAL INTERPRETATION
Drilling at Fiery Creek confirms the presence of a broad, mineralised structural corridor and supports
an emerging hybrid structural–intrusive mineral system model. Key observations include:
A ~50 m wide, steeply dipping shear zone hosting vein- and shear-controlled Cu–Ag
mineralisation (Figures 2 and 3), demonstrating strong structural control on mineralisation
continuity and geometry.
The presence of associated aplite intrusive bodies, including zones with miarolitic cavities,
which locally contain visible copper sulphides, indicating a magmatic contribution to the
mineralising system.
Locally enhanced grades where shear-hosted mineralisation intersects or is overprinted by
intrusive-related mineralisation (Figures 4 and 5), suggesting a spatial and genetic relationship
between deformation and magmatic processes.
ASX RELEASE | ASX:EMU
P a g e | 3
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Collectively, these results support interpretation of the system as a hybrid structural–intrusive
mineral system, where mineralisation is controlled by the interaction of deformation-related fluid
pathways and intrusive emplacement, resulting in zones of grade enhancement at structural–
intrusive intersections.
Table 1: Drillhole Intersection Highlights (refer to Appendix A)
Hole ID From (m) To (m) Significant Intersections (0.1% Cu Cut-Off)
25YFC001 48 49 1m at 1.02% Cu + 23.4g/t Ag from 48m
25YFC002 3 4 1m at 0.16% Cu from 3m
49 62 13m at 0.49% Cu + 9.7g/t Ag from 49m
49 55 Incl. 6m at 0.84% Cu + 16.5 g/t Ag from 49m
50 51 Incl. 1m at 1.29% Cu + 26.9 g/t Ag from 50m
93 96 3m at 0.12% Cu from 93m
119 120 1m at 0.20% Cu + 3.0 g/t Ag from 119m
25YFC003 18 20 2m at 0.11% Cu + 4.6 g/t Ag from 18m
24 26 2m at 0.15% Cu + 4.7 g/t Ag from 24m
29 30 1m at 0.10% Cu from 29m
37 50 13m at 0.25% Cu + 5.3 g/t Ag from 37m
37 38 Incl. 1m at 0.49% Cu + 12.5 g/t Ag + 0.14% Zn from 37m
43 44 And 1m at 0.65% Cu + 7.3 g/t Ag from 43m
81 85 4m at 0.22% Cu + 4.3 g/t Ag from 81m
94 95 1m at 0.11% Cu from 94m
114 115 1m at 0.17% Cu from 114m
25YFC004 40
41
43
42
3m at 0.60% Cu + 13.3g/t Ag from 40m
Incl. 1m at 1.5% Cu + 31.3g/t Ag from 41m
97 98 1m at 0.12% Cu + 2.80g/t Ag from 97m
25YFC006 30 33 3m at 0.27% Cu + 5.35g/t Ag from 30m
40 41 1m at 1.00% Cu + 27.97g/t Ag from 40m
64 65 1m at 0.11% Cu + 2.21g/t Ag from 64m
25YFC007 30 31 1m at 0.60% Cu + 9.00g/t Ag from 30m
85 86 1m at 0.36% Cu + 7.1g/t Ag from 85m
92 93 1m at 0.19% Cu + 2.90g/t Ag from 92m
ASX RELEASE | ASX:EMU
P a g e | 4
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Hole ID From (m) To (m) Significant Intersections (0.1% Cu Cut-Off)
25YFC009 65 66 1m at 0.15% Cu + 1.8g/t Ag from 65m
70 71 1m at 0.15% Cu + 1.6g/t Ag from 70m
72 73 1m at 0.12% Cu + 1.5g/t Ag from 72m
80 81 1m at 0.11% Cu + 1.3g.t Ag from 80m
97 99 2m at 0.13% Cu + 1.3g/t Ag from 97m
100 102 2m at 0.11% Cu + 1.5g/t Ag from 100m
115 118 3m at 0.15% Cu + 2.5g/t Ag from 115m
128 132 4m at 0.12% Cu + 1.9g.t Ag from 128m
133 135 2m at 0.14% Cu + 1.7g.t Ag from 133m
25YFC010 87 88 1m at 0.10% Cu + 1.6g.t Ag from 87m
89 93 4m at 0.14% Cu + 2.6g.t Ag from 89m
25YFC012 0 1 1m at 0.15% Cu + 0.7g/t Ag from 0m
9 10 1m at 0.15% Cu + 1.8g/t Ag from 9m
100 101 1m at 0.11% Cu + 1.5g/t Ag from 100m
Table 2: Fiery Creek Drill Collar Table
Drillhole ID Drilling Method Easting Northing Dip/Azimuth (Deg) Depth (m)
25YFC001 RC 774577 8007990 -550
/900
192
25YFC002 RC 774582 8007720 -500
/640
192
25YFC003 RC 774575 8007507 -500
/780
174
25YFC004 RC 774641 8007998 -510
/830
192
25YFC005 RC 774502 8007273 -520
/830
174
25YFC006 RC 774906 8007973 -500
/2500
150
25YFC007 RC 775012 8007741 -530
/900
174
25YFC008 RC 775074 8007517 -500
/500
114
25YFC009 RC 775192 8007262 -500
/500
186
25YFC010 RC 775295 8007155 -500
/700
150
25YFC011 RC 775541 8007164 -500
/1000
130
25YFC012 RC 775384 8007406 -500
/700
150
25YFD013
Twin
25YFC002
Diamond 774582 8007720 -500
/680
143.8
25YFD014 Diamond 774570 8007720 -80/75 150.2
Total 2,272
ASX RELEASE | ASX:EMU
P a g e | 5
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Figure 2: Location of Drill Sites and Surface Geochemistry1
at Fiery Creek Prospect
1
ASX Announcement Dated 11 March 2025 – Yataga Copper Project – Exploration Update
ASX RELEASE | ASX:EMU
P a g e | 6
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Figure 3: Plan View of 25YFC002 and 25YFC003 Drill Sites and Surface Geochemistry1
ASX RELEASE | ASX:EMU
P a g e | 7
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Figure 4: Cross-Section of RC Drillhole 25YFC002
ASX RELEASE | ASX:EMU
P a g e | 8
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Figure 5: Cross-Section of RC Drillhole 25YFC003
ASX RELEASE | ASX:EMU
P a g e | 9
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
REVISED GEOLOGICAL MODEL
The geological model for Fiery Creek has been updated based on integrated drilling, mapping and
geophysical data. The system is now interpreted to comprise:
A steeply dipping feeder zone hosting shear-controlled Cu–Ag mineralisation, representing the
primary fluid conduit.
Multiple shallow-dipping mineralised splays or “branches” emanating from the main
structure, reflecting lateral dispersion of mineralising fluids.
Host rocks comprising a granodiorite intrusive complex (Figure 6), providing the principal
lithological framework for mineralisation.
Widespread aplite dykes, sills and intrusive “kitchen” zones, interpreted as late-stage
magmatic phases associated with fluid generation and metal transport.
This overall geometry is best described as a “Christmas Tree”-style mineral system, characterised
by a steep central feeder with multiple mineralised o shoots. The interpretation is strongly
supported by drilling results, surface mapping and coincident geophysical responses.
Figure 6: Idealised Geological Cross-Section at Fiery Creek Prospect
ASX RELEASE | ASX:EMU
P a g e | 10
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
GEOCHEMISTRY AND SYSTEM SIGNATURE
Assay data and geological logging define a Cu–Ag–Bi–Te dominant geochemical signature,
consistent with a porphyry-related magmatic–hydrothermal system. Observed metal zonation
indicates:
A higher temperature Cu-dominant core.
Peripheral polymetallic signatures, including As, Sb, Pb and Zn.
This geochemical signature aligns with broader datasets across the Yataga area, where:
A large-scale Cu anomaly (>8 km²) has been delineated.
Mineralisation is spatially associated with intrusive phases, structural corridors and aplite
dyke swarms.
SIGNIFICANCE OF STAGE 1 DRILLING RESULTS
The key outcome of the drilling programme is not limited to discrete high-grade intercepts, but rather
the definition of a coherent and scalable mineral system:
1. Validation of a Large Mineralised System
Drilling confirms that Fiery Creek is situated within a fertile intrusive complex.
Mineralisation demonstrates systematic distribution and geological predictability.
2. Identification of Controls on Grade
Elevated grades are consistently associated with a). Structural intersections; and b). Shear-
intrusive contacts.
3. Vectoring Toward Stronger Targets
Geological and geochemical data indicate increasing mineralisation potential at depth; and
additional potential within adjacent or untested intrusive centres.
IMPLICATIONS FOR UPCOMING 2026 YATAGA VALLEY EXPLORATION
The Fiery Creek results materially de-risk and enhance the prospectivity of the broader Yataga Valley
programme. Key implications include:
Confirmation of both steep, shear-hosted Cu systems and shallow-dipping intrusive-hosted
mineralisation styles.
Direct correlation between mineralisation and geophysical responses, including IP
chargeability anomalies and magnetic lows associated with intrusive centres.
At Yataga Valley, geophysical datasets define a large, coherent chargeability anomaly interpreted to
represent sulphide mineralisation. This includes:
A broad, shallow-dipping “kitchen” zone developed beneath the pluton roof.
ASX RELEASE | ASX:EMU
P a g e | 11
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Steep feeder structures along the margins of the system.
This conceptual model is directly consistent with observations at Fiery Creek and provides a robust
framework for ongoing exploration and drill targeting across the Yataga Valley project area.
NEXT STEPS
The immediate focus is on completing outstanding analytical and interpretive work to support the
next phase of drilling:
1. Final assay results from two diamond drillholes remain pending and will be incorporated into
the evolving geological model.
2. Development of an integrated 3D geological and geophysical model to consolidate drilling,
mapping and geophysical datasets into a single predictive framework.
3. Ongoing refinement of drill targeting, including:
a. Follow-up drilling at Fiery Creek to test extensions of the identified mineralised system.
b. Prioritisation and optimisation of drill targets across the Yataga Valley project area.
FOCUS OF 2026 YATAGA VALLEY DRILLING PROGRAMME
Exploration activities in 2026 will transition toward systematic testing of higher-order targets at
Yataga Valley, informed by the Fiery Creek results. The programme will focus on:
Intrusive centres interpreted to represent potential mineralisation “source” zones.
Chargeability anomalies identified from geophysical surveys, interpreted as sulphide-rich
domains.
Structural intersections considered prospective for fluid focusing and grade enhancement.
CONCLUSION
Fiery Creek has advanced from a surface anomaly to a well-defined and interpreted mineral system.
The programme has:
Established the geometry and controls of mineralisation.
Identified clear vectors toward higher-value target zones.
Increased confidence in the planned Yataga Valley drilling programme.
These outcomes provide a strong foundation for a more targeted and potentially higher-impact
drilling campaign at Yataga Valley in 2026.
ASX RELEASE | ASX:EMU
P a g e | 12
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
MANAGING DIRECTOR AND CEO - DOUG GREWAR COMMENTS:
“The Fiery Creek drilling programme has delivered a clear understanding of the geological system
and the controls on mineralisation.Early drilling has returned variable grades with the work indicating
a potentially large Cu–Ag system. Importantly, these results materially upgrade our confidence in
the Yataga Valley targets, where co incident geophysics and geochemistry indicate the possibility of
a significantly larger mineralised system.”
AUTHORISED FOR RELEASE BY THE BOARD
For further information, please contact:
Doug Grewar, Managing Director and Chief Executive O icer
info@emunl.com.au
Investors can sign into our interactive investor hub and join in on the
conversation with Emu NL.
https://investorhub.emunl.com.au/auth/signup
Competent Person Statement:
The information in this report that relates to Exploration Results and Mineral Resources is based upon
and fairly represents information compiled by or compiled under the supervision of Peter Swiridiuk -
Member of the Aust. Inst. of Geoscientists. Peter Swiridiuk is a Non-Executive Director of Emu NL.
Peter Swiridiuk has su icient experience which is relevant to the type of mineralisation and type of
deposit under consideration to qualify as Competent Person as defined in the 2012 Edition of the
“Australasian Code of Reporting Exploration Results, Mineral Resources and Ore Resources”. Peter
Swiridiuk consents to the inclusion in the report of the matters based on the information in the form
and context in which it appears. Additionally, Mr Swiridiuk confirms that the entity is not aware of any
new information or data that materially a ects the information contained in the ASX releases referred
to in this report.
ASX RELEASE | ASX:EMU
P a g e | 13
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
APPENDIX A - JORC TABLE 1
Section 1 - Sampling Techniques and Data
(Criteria in this section apply to all succeeding sections.)
Criteria Explanation Commentary
Sampling
techniques
Nature and quality of sampling (e.g. cut channels,
random chips, or specific specialised industry standard
measurement tools appropriate to the minerals under
investigation, such as down hole gamma sondes, or
handheld XRF instruments, etc.). These examples
should not be taken as limiting the broad meaning of
sampling.
Include reference to measures taken to ensure sample
representivity and the appropriate calibration of any
measurement tools or systems used.
Aspects of the determination of mineralisation that are
Material to the Public Report. In cases where ‘industry
standard’ work has been done this would be relatively
simple (e.g. ‘reverse circulation drilling was used to
obtain 1 m samples from which 3 kg was pulverised to
produce a 30 g charge for fire assay’). In other cases,
more explanation may be required, such as where there
is coarse gold that has inherent sampling problems.
Unusual commodities or mineralisation types (e.g.
submarine nodules) may warrant disclosure of detailed
information.
- Reverse Circulation Percussion (RCP) drilling was used to produce a 1m bulk sample (~25kg) which was
collected in plastic bags. A representative sample of 3kg to 4g was collected from the 1m bulk sample, via a
splitter attached to the cyclone at the rig. A Through the Bit, Face Sampling Hammer was utilised by the RCP
rig.
- A subsample of each 1m sample was passed through a 1mm sieve and 100g or so of fines was placed in a
Kraft envelope and retained as a representative 1m sample for screening for base metals and major elements
by off-site PXRF analysis in an independent facility at Terra Search in Townsville.
- The samples submitted for analysis were nominally 3kg in weight. At the start of the drilling program at
Yataga, all of the samples for drillholes YFCC002 and YFC003 were submitted to Intertek Laboratories for
analysis, without PXRF screening.
- Subsequent analyses of samples from Yataga involved PXRF analysis of each of the representative 1m sub-
samples and then sub-divided into: (1) samples with elevated copper (generally greater than 200ppm Cu or
so) which were retained as 1m samples, and (2) samples with low Cu, which were composited as 4 x 1m
samples by means of a Jones splitter with the order of 4 x 3kg samples being composited to 1 x 3kg sample
representing the 4m sample interval. For each drillhole measured with PXRF, five OREAS standards were
measured at the beginning and end of each reading run per drillhole.
- EMU deployed their own internal Certified Reference Materials every 30m and Blanks at the beginning of each
drillhole. Intertek Laboratories used six certified reference materials, control blanks and re-check samples
for each drillhole.
- Industry standard sampling and logging techniques have been used for these samples by a suitably qualified
geologist. Sieved subsample of the 25kg split was used for the geological logs. Each meter was sieved and
rock chips collected in chip trays, each containing 20 metres of chips.
ASX RELEASE | ASX:EMU
P a g e | 14
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Criteria Explanation Commentary
Drilling
techniques
Drill type (e.g. core, reverse circulation, open-hole
hammer, rotary air blast, auger, Bangka, sonic, etc.) and
details (e.g. core diameter, triple or standard tube, depth
of diamond tails, face-sampling bit or other type,
whether core is oriented and if so, by what method, etc.).
- Drilling was undertaken using a Reverse Circulation Percussion (RCP) drill rig. A face sampling hammer of
approximately 5½ inch diameter was used.
Drill sample
recovery
Method of recording and assessing core and chip
sample recoveries and results assessed.
Measures taken to maximise sample recovery and
ensure representative nature of the samples.
Whether a relationship exists between sample recovery
and grade and whether sample bias may have occurred
due to preferential loss/gain of fine/coarse material.
- Sample recovery was visually assessed by bulk sample weight and volume and was consistent and high.
- Sample recovery was maximised by the use of face sampling hammers and bymaintaining air pressure within
the hole, minimising water ingress into the hole.
- No relationship between sample recovery and grade is known at this stage.
Logging Whether core and chip samples have been geologically
and geotechnically logged to a level of detail to support
appropriate Mineral Resource estimation, mining
studies and metallurgical studies.
Whether logging is qualitative or quantitative in nature.
Core (or costean, channel, etc.) photography.
The total length and percentage of the relevant
intersections logged.
- All intervals were geologically logged to a level that could be used to support a mineral resource, however at
this early stage of exploration, it is unknown if with additional drilling a Mineral Resource could be estimated.
- Logging is qualitative in nature from RCP chips every 1 metre.
Sub-sampling
techniques
and sample
preparation
If core, whether cut or sawn and whether quarter, half or
all core taken.
If non-core, whether riffled, tube sampled, rotary split,
etc. and whether sampled wet or dry.
For all sample types, the nature, quality and
appropriateness of the sample preparation technique.
Quality control procedures adopted for all sub-sampling
stages to maximise representivity of samples.
- A 1m bulk sample (~25kg) was collected in plastic bags direct from the cyclone at the rig side. A
representative sample of 3kg to 4g was collected from the 1m bulk sample, via a cone splitter attached to
the cyclone.
- A subsample of each 1m sample was passed through a 1mm sieve and 100g or so of fines was placed in a
Kraft envelope and retained as a representative 1m sample for screening for base metals and major elements
by off-site PXRF analysis in an independent facility at Terra Search in Townsville. All samples for drillholes
YFCC002 and YFC003 were submitted to Intertek Laboratories for analysis, without PXRF screening.
ASX RELEASE | ASX:EMU
P a g e | 15
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Criteria Explanation Commentary
Measures taken to ensure that the sampling is
representative of the in situ material collected, including
for instance results for field duplicate/second-half
sampling.
Whether sample sizes are appropriate to the grain size
of the material being sampled.
- Subsequent analyses of samples from Yataga involved PXRF analysis of each of the representative 1m sub
samples and then sub-divided into: (1) samples with elevated copper (generally greater than 200ppm Cu or
so) which were retained as 1m samples, and (2) samples with low Cu, which were composited as 4 x 1m
samples by means of a Jones splitter with the order of 4 x 3kg samples being composited to 1 x 3kg sample
representing the 4m sample interval.
- The sampling and sub-sampling techniques are considered appropriate.
- Sample sizes are appropriate for the style of mineralisation being sought.
Quality of
assay data and
laboratory
tests
The nature, quality and appropriateness of the assaying
and laboratory procedures used and whether the
technique is considered partial or total.
For geophysical tools, spectrometers, handheld XRF
instruments, etc., the parameters used in determining
the analysis including instrument make and model,
reading times, calibrations factors applied and their
derivation, etc.
Nature of quality control procedures adopted (e.g.
standards, blanks, duplicates, external laboratory
checks) and whether acceptable levels of accuracy (i.e.
lack of bias) and precision have been established.
- Preparation of rock chip samples involves crushing splitting and grinding at Intertek/Genalysis lab,
Townsville. The total amount of economic metals and pathfinder elements tied up in sulphides and oxides
such as U, Th, Cu, Pb, Zn, Ag, As, Mo, Bi, S is captured by the 4-acid digest method ICP finish. Mass
spectrometry (MS) ensures low level detection and REE are also captured for drillhole samples YFC002 and
003 only. This is regarded as a total digest method and is checked against QA-QC procedures which also
employ these total digestion techniques. Major elements which are present in silicates, such as K, Ca, Fe, Ti,
Al, Mg are also digested by the 4-acid digest Total method.
- PXRF analysis has been utilized to provide multi-element data for the prospect in order to quantitatively
screen the drill samples. After PXRF analysis those zones with elevated Cu are submitted for 1m analysis.
Those with only background copper are composited as 4m samples. 1mm fines from sub sampling
percussion drill sample are considered appropriate and representative samples to provide preliminary
chemical analysis to guide exploration targeting.
- PXRF Analysis is carried out in a controlled environment in air-conditioned Terra Search offices in Townsville.
The instrument used is Terra Search’s portable Niton XRF analyser (Niton ‘trugeo’ analytical mode) analysing
for a suite of 40 major and minor elements. The PXRF equipment is set up on a bench and the sub-sample
(loose powder in a thin clear plastic freezer bag) is placed in a lead-lined stand. An internal detector auto-
calibrates the portable machine, and Terra Search standard practice is to instigate recalibration of the
equipment every 2 to 3 hours.
- PXRF Readings are undertaken for 60 seconds on a circular area of approximately 1cm diameter. High results
for copper are duplicated after re-mixing the sample
- PXRF measures total concentration of particular elements in the sample. Reading of the X-Ray spectra is
affected by interferences between different elements. The matrix of the sample e.g., iron content has to be
taken into account when interpreting the spectra. The reliability and accuracy of the PXRF results are
checked regularly by reference to known standards. There are some known interferences relevant to
ASX RELEASE | ASX:EMU
P a g e | 16
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Criteria Explanation Commentary
particular elements E.g., W & Au; Th & Bi, Fe & Co. Awareness of these interferences is taken into account
when reviewing PXRF results. No PXRF are reported in this announcement as they were used as a guide for
compositing. All relevant independent laboratory assay results have been reported.
- QAQC samples are monitored on a batch-by-batch basis, Terra Search has well-established sampling
protocols including the insertion of blanks (both coarse & pulped), certified reference material (CRM
standards). Terra Search quality control included determinations on certified OREAS samples interspersed
at regular intervals through the sample suite of the commercial laboratory batch.
- Assay quality was monitored using pulp blanks, as well as certified reference materials (CRMs) at a range of
copper & gold grades. Pulp blank results indicated no material contamination of samples from sample
preparation or during the analytical process. CRM results were within 3 standard deviations of certified
values. No material systematic bias nor other accuracy related issues were identified.
- With the Intertek Lab batches Standards are checked on receipt of results. Results that have been returned
to date are found to be within acceptable tolerances. Laboratory assay results for these quality control
samples are within 5% of accepted values. Besides the independent Certified reference OREAS materials
that Emu NL has independently inserted into the sample batches every 30m, Intertek Laboratories has also
used a number of internal lab standards and check assays.
- The selected assay methods are appropriate for the mineralisation encountered.
- Geophysical tools used (magnetic susceptibility meter, handheld XRF) are calibrated prior to use on site.
- Only the assay results from Independent Intertek Laboratories have been quoted in this announcement using
Fire Assay 50g for Au and 4-acid digest method ICP finish for all other elements.
Verification of
sampling and
assaying
The verification of significant intersections by either
independent or alternative company personnel.
The use of twinned holes.
Documentation of primary data, data entry procedures,
data verification, data storage (physical and electronic)
protocols.
Discuss any adjustment to assay data
- Significant intersections reported in this release have been made by a senior geologist and have been verified
by an alternative company geologist/director.
- For all RC drillholes, geological logs and sampling have been recorded on paper and then entered into the
Company’s digital system. The data entry has been validated by at least two company geologists.
- No assay adjustments have been made.
Location of
data points
Accuracy and quality of surveys used to locate drill holes
(collar and down-hole surveys), trenches, mine
- Hand-held GPS was used to site the holes with an accuracy of +/- 5m. Downhole surveys have been collected
on 5m intervals using a Reflex multi-shot gyro tool.
- The geodetic grid system used was UTM MGA94, Zone 54.
ASX RELEASE | ASX:EMU
P a g e | 17
www.emunl.com.au || info@emunl.com.au || PO Box 1112, West Perth, WA, 6872 || ABN 50 127 291 927
Criteria Explanation Commentary
workings and other locations used in Mineral Resource
estimation.
Specification of the grid system used.
Quality and adequacy of topographic control.
- Topographic control is based on 0.1m Airborne Lidar surveys.
Data spacing
and
distribution
Data spacing for reporting of Exploration Results.
Whether the data spacing and distribution is sufficient to
establish the degree of geological and grade continuity
appropriate for the Mineral Resource and Ore Reserve
estimation procedure(s) and classifications applied.
Whether sample compositing has been applied.
- Drilling is currently wide spaced and is not close enough to support a Mineral Resource estimate.
- Some samples where no visual sulphide mineralisation was logged.
- No compositing of samples from drillholes YFC002 and YFC003 has been undertaken. Samples from all other
drillholes will be analysed with and XRF to assist in determining which are to be composited. Any anomalous
assay results from composite samples will be re-assayed for each metre of sample.
Orientation of
data in relation
to geological
structure
Whether the orientation of sampling achieves unbiased
sampling of possible structures and the extent to which
this is known, considering the deposit type.
If the relationship between the drilling orientation and
the orientation of key mineralised structures is
considered to have introduced a sampling bias, this
should be assessed and reported if material.
- Drilling has been designed to intersect perpendicular to the geochemical copp
Share your feedback
Discover