Significant and Pervasive Copper Mineralisation Fiery Creek
Released
Released
Announcement PDF
ASX RELEASE | ASX:EMU
4 June 2024
GEORGETOWN PROJECT UPDATE
“Significant and Pervasive” Copper Mineralisation Discovery
Confirmed by pXRF Geochemistry Survey at Fiery Creek
Highlights
pXRF geochemistry programme has confirmed an extensive broad copper mineralised
zone
The mineralised discovery zone, tested by pXRF over soil, termite mound and rock chip
sample mediums, covers an area approximately 720m long x 480m wide
The highest copper grade recorded was 32.5% from 27 rock chip samples
Significant copper grades up to 2,484ppm were recorded from pXRF soil samples whilst
the highest termite mound sample recorded 1,674ppm copper
Samples from the programme have been dispatched to the laboratory for wet
geochemistry testing to confirm and correlate the pXRF in field results
Results indicate the mineralisation is significant and pervasive between outcropping
high-grade copper veining and stockwork veining within the discovery zone and is
interpreted to be a subset of a much broader and significant system
Addi onal sampling has defined a mineralised, copper anomalous, shear zone extending
at least 2.5 km to the SE
Drone LiDAR and photogrammetry works now complete with data processing underway
Ground pole dipole, IP resistivity and MT survey scheduled for August
Airborne aeromagnetic survey over Yataga Igneous Complex scheduled between July
and October
Maiden drilling programme planned for October 2024 following ground geophysics
assessment
EMU NL (“EMU” or “the Company”) is pleased to provide an update on recent exploration
work completed at the Company’s Fiery Creek Copper Prospect located within the
Georgetown Project in North Queensland.
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
1
Portable XRF (pXRF) geochemistry results have extended previously defined high-grade
copper mineralisation and aided the interpretation of structural controls. The pXRF
programme forms part of a wider suite of geochemical surveys designed to confirm and
extend the known mineralisation of this significant copper porphyry discovery.
EMU Non-Executive Chairman Peter Thomas commented,
“The initial pXRF results from the field are highly encouraging with broad disseminated copper
mineralisation reported from the discovery zone potentially providing EMU with an immediate
drill target. Whilst geophysics planned over the next few months will tighten drilling vectors, we
are optimistic the results support our interpretation that Fiery Creek could host a large bulk multimillion tonne copper – silver porphyry system.
The pXRF survey was designed to extend our previous laboratory analysed geochemistry surveys
results. The advantage of pXRF is that it gives immediate feedback in field which can substantially
reduce on ground cost and time. The confirmation of significant copper mineralisation in the
discovery zone by pXRF is only bettered by the fact that pXRF results from termite mounds in the
adjacent zones suggest an even broader envelope of copper mineralisation than first thought.”
Geochemistry Programme
EMU successfully completed a soil sampling program on an 80m x 20m grid, covering the
discovery area of the Fiery Creek Copper Prospect (FCCP). The soil sampling survey measures
720m (north-south) by 480m (east-west). Soil sampling was supplemented by the collec on of
addi onal rock chip and termite mound samples.
The sampling followed standard geochemical explora on procedures by taking samples below
the sheetwash sand and gravels in the clay horizon developed immediately above weathered
bedrock. All samples were analysed in the field by pXRF. The soil geochemical sampling grid is
shown below in Figure 3.
Understanding these results in their geologic context is important to ascertain where they sit
in respect of the overall explora on poten al of the large prospect area.
Figure 1 shows the loca on of the FCCP within the Yataga Igneous Complex (YIC) as outlined
by the inverted aeromagne c signature, which was caused by the intrusion of the YIC at
around 286 Ma (Lower Permian age) when the magne c pole of the Earth was reversed.
Figure 2 shows the YIC aeromagne c signature, and the structural geologic features as
interpreted by Consultant Economic Geologist, Mr Nigel Maund. Most noteworthy is the
impact of the late NE striking shear corridor, which has geologically modified the YIC and
impacted the Fiery Creek Cu–Bi–Ag mineralised shear zone. These shear zones are hos ng the
mineralisa on and are a very important structural feature that will focus EMU’s explora on to
their occurrences across the broader discovery area in future work.
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
2
Emu explored the area to the SE of the FCCP and located a substan al zone of copper
mineralisa on which is most likely the faulted con nua on of the FCCP as suggested in this
structural analysis. This area will be systema cally soil sampled during the next quarter.
Figure 1: The TMI aeromagne c map showing the ovoid (8 x 5 km) Yataga Igneous Complex (YIC) and
the loca on of the ini al rock chip sampling (green triangles) at the Fiery Creek Copper
Prospect.
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
3
Figure 2: EMU’s structural geologic interpreta on of the YIC TMI aeromagne c map. The key structural
geologic features iden fied are the earlier WNW striking shear corridor which brackets the
FCCP. This corridor has been modified by the subsequent ENE striking largely right lateral
le lateral shear corridor which impacts the en re YIC. Importantly these structural shear
zones control FCCP mineralisa on and are responsible for controlling late emplacement of a
porphyry intrusive event. This intrusive is interpreted to be located to the immediate south
the FCCP, and displaces the FCCP copper mineraliza on towards the east.
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
4
Figure 3: A summary geologic map of the Fiery Creek Copper Prospect (FCCP) discovery area showing
the loca on of some original rock chip samples (diamonds) and the recently implemented soil sampling
grid and the handheld pXRF copper results given in ppm and coloured according to the legend on the
Figure. The white line shows the outline of the copper anomalous zone. The offse ng of the
mineralized zone shows the consistent right lateral (dextral) offse ng of the host FCCP zone.
The results of the soil sampling have defined a copper anomalous shear zone, developed
within the moderately potassic altered (bio te + K feldspar) medium grained, equigranular,
granodiorite. This shear zone strikes NNW (340°) and generally dips ver cally in outcrop. As
Figure 3 shows, the mineralized shear zone is offset by elements of an ENE striking (50° to 60°)
shear corridor.
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
5
Soil samples from FCCP were taken from the red brown clay hardpan developed below surficial
unconsolidated sheetwash sand and gravels. Generally, soil sample Cu results exhibit values at
a frac on of those collected in bedrock oxide copper + goethite (a er pyrite) mineralisa on.
Hence, unsurprisingly, the soil values vary between 100 and 2484 ppm Cu with significantly
anomalous values being above 300 ppm, as compared to values up to 32.5% returned from
rock chip samples taken from sub-crop and outcrop. This implies that the shear zone hosted
mineralisa on, within the ini al discovery area of the FCCP, varies from a width of 60 m to a
maximum of 150 m over a sampled strike length of 480 m.
Termite mound geochemistry has been undertaken to the east and southeast of the discovery
FCCP area where further copper mineralisa on has been discovered. Explora on in the areas
outside the primary zone remains a work in progress and will be reported upon in detail once
addi onal sampling programmes have been completed.
It should be stated that explora on of the FCC prospect is very much in its early days, with a
considerable amount of grid-based soil sampling yet to be completed, along with
accompanying detailed geologic mapping. LiDAR & orthophotography drone surveying was
recently completed and the data taken from the programme is currently undergoing
processing.
Ground geophysical work is scheduled to be undertaken during the coming quarter following
geochemical, LiDAR and geologic mapping work being completed and analysed to iden fy
specific targets for appropriate IP and MT geophysical surveys.
Upon the comple on of geochemical and geophysical surveys over the broader Project area,
a maiden drilling program is envisaged to be undertaken towards the end of this year, perhaps
as early as October.
Termite Mound Sampling
Sampling of termite mounds is an extremely effective exploration method to rapidly assess
areas prospective for gold and base metal mineralisation. Termites collect organic and
inorganic material for nest construction from burrowed corridors within the soil, bringing
material upwards from deep-seated environments. Previous studies1 suggest termites
transport materials from depths of over 8.5m and up to 70m. The height of termitaria is
directly proportional to the depth of burrowed materials from sub surface environment. As
the termites collect material from underling rocks and mineralisation, anomalies defined by
sampling of termitaria represent in situ mineralisation.
Coventry, Holt and Sinclair, 1988, Nutrient cycling by mound building termites in low fertility soils of semi-arid tropical
Australia, Australian Journal of Soil Research 26(2) 375 - 390
1
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
6
Figure 4. An example of a typical termite mound located within the Georgetown Fiery Creek
Copper Prospect area
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
7
AUTHORISED FOR RELEASE BY THE BOARD
For further information, please contact:
Doug Grewar
Chief Executive Officer
EMU NL
info@emunl.com.au
Investors can sign into our interactive investor hub and join in on the conversation with Emu
NL.
https://investorhub.emunl.com.au/auth/signup
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
8
EMU NL
COMPETENT PERSON’S STATEMENT
ABN 50 127 291 927
The information in this report that relates to exploration results is based
on, and fairly represents information and supporting documentation
prepared by compiled by Mr Nigel Maund, a Competent Person who is
consulting economic geologist. Mr Maund is a Fellow of the Australian
Institute of Geoscientists, a Fellow of the Australian Institute of Mining and
Metallurgy. Mr Maund is a consultant to EMU NL and has sufficient
experience in the activity which he is undertaking to qualify as a Competent
Person as defined in the 2012 edition of the “Australasian Code for
Reporting of Exploration Results, Mineral Resources and Ore Reserves”. Mr
Maund consents to the inclusion herein of the matters based upon his
information in the form and context in which it appears.
ASX Codes: EMU and EMUCA
10 Walker Ave
West Perth, WA 6005
T +61 8 9226 4266
E info@emunl.com.au
PO Box 1112
West Perth, WA 6872
Fully paid shares (listed)
76,872,966 (net of 620,000 the subject of the
ATM which EMU can buy back for nil
consideration)
Contributing Shares (listed)
1,349,586 paid to $0.90, $0.90 to pay
Contributing Shares (Unlisted)
1,166,670 paid to $0.003, $1.20 to pay, no call
before 31 December 2025
Options (unlisted)
5,748,486 options to acquire fully paid shares,
exercisable at $0.30 each, on or before
7 October 2024
10,579,193 options to acquire fully paid shares,
exercisable at $0.09 each, on or before
31 December 2026
Performance Rights (Unlisted)
1,619,051 performance rights in relation to
acquisition of Gnows Nest project (can be
repurchased for $20k if Gnows Nest disposed of
before 22.9.2025)
FORWARD LOOKING STATEMENTS
As a result of a variety of risks, uncertainties and other factors, actual events
and results may differ materially from any forward looking and other
statements herein not purporting to be of historical fact. Any statements
concerning mining reserves, resources and exploration results are forward
looking in that they involve estimates based on assumptions. Forward
looking statements are based on management’s beliefs, opinions, and
estimates as of the respective dates they are made. The Company does not
assume any obligation to update forward looking statements even where
beliefs, opinions and estimates change or should do so given changed
circumstances and developments.
NEW INFORMATION OR DATA
EMU confirms that it is not aware of any new information or data that
materially affects the information included in the original market
announcements and, in the case of estimates of Mineral Resources, which
all material assumptions and technical parameters underpinning the
estimates in the relevant market announcement continue to apply and have
not materially changed. The Company confirms that the form and context in
which the Competent Person’s findings are presented have not
materially changed from the original market announcement.
Directors:
Peter Thomas
Non-Executive Chairman
Terry Streeter
Non-Executive Director
Gavin Rutherford
Non-Executive Director
Tim Staermose
Non-Executive Director
Investor enquiries:
Doug Grewar CEO
M +61 419 833 604
E info@emunl.com.au
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
9
ASX RELEASE | ASX:EMU
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
10
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
11
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
12
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
13
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
14
Table 3: Empirical pXRF (Nikon XL5 Plus) Analysis Results - Crushed Rock
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
15
Appendix 2 JORC Tables
Section 1 Sampling Techniques and Data
(Criteria in this section apply to all succeeding sections.)
Criteria
JORC Code explanation
Commentary
Sampling
techniques
Nature and quality of sampling (eg cut
channels, random chips, or speci c
specialised industry standard measurement
tools appropriate to the minerals under
investigation, such as down hole gamma
sondes, or handheld XRF instruments, etc).
These examples should not be taken as
limiting the broad meaning of sampling.
Include reference to measures taken to
ensure sample representivity and the
appropriate calibration of any measurement
tools or systems used.
Aspects of the determination of
mineralisation that are Material to the
Public Report.
In cases where ‘industry standard’ work
has been done this would be relatively
simple (eg ‘reverse circulation drilling was
used to obtain 1 m samples from which 3
kg was pulverised to produce a 30 g
charge for re assay’). In other cases more
explanation may be required, such as
where there is coarse gold that has
inherent sampling problems. Unusual
commodities or mineralisation types (eg
submarine nodules) may warrant disclosure
of detailed information.
Drill type (eg core, reverse circulation,
open-hole hammer, rotary air blast, auger,
Bangka, sonic, etc) and details (eg core
diameter, triple or standard tube, depth of
diamond tails, face-sampling bit or other
type, whether core is oriented and if so, by
what method, etc).
Method of recording and assessing core
and chip sample recoveries and results
assessed.
Measures taken to maximise sample
recovery and ensure representative nature
of the samples. Whether a relationship
exists between sample recovery & grade
and whether sample bias may have
occurred due to preferential loss/gain of
ne/coarse material.
Whether core and chip samples have been
geologically and geotechnically logged to a
level of detail to support appropriate
Mineral Resource estimation, mining
studies and metallurgical studies.
Whether logging is qualitative or
quantitative in nature. Core (or costean,
channel, etc) photography.
The total length and percentage of the
No drilling was done.
No drilling was done.
All samples were logged geologically by Company
geologists, using EMU logging codes.
Logging is both qualitative and quantitative in nature,
and includes lithology, mineralogy, mineralisation,
weathering, & colour.
Photographs taken for each sample and stored in a
database.
In relation to the disclosure of visual mineralisation,
the Company cautions that visual estimates of mineral
Drilling techniques
Drill sample
recovery
Logging
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
No drill assays are presented in this update.
Traditional soil samples as well as termite mound
samples were collected at 20m spacings. A further
200-300g sample (where submitted) will be crushed
and a sub-fraction obtained for pulverisation.
Samples have been dispatched to both LabWest and
Nagrom laboratories in Perth.
Rock samples were collected where available and for
both lithological identi cation and geochemical
analysis.
All sample mediums were sieved to passing -1mm
mesh before pXRF analysis.
Field samples were located using hand-held GPS.
Sampling was carried out under Emu NL protocols
and QAQC procedures as per current industry
practice.
Sample quality was supervised by experienced eld
geologists and eld technicians under geologist
supervision.
All LabWest samples will be analysed using
Microwave digest (MD), Inductively Coupled Plasma
Mass Spectrometry and Inductively Coupled Plasma
(ICP) Mass Spectrometry (MS) and Optical Emission
Spectrometry (OES) to nish. 62 element analysis by
ICP-MS/OES.
All Nagrom samples will be analysed using a 50g Fire
assay method.
ASX Code: EMU
ABN: 50 127 291 927
16
Criteria
JORC Code explanation
Commentary
relevant intersections logged.
Sub-sampling
techniques and
sample
preparation
Quality of assay
data and
laboratory tests
Veri cation of
sampling and
assaying
Location of data
points
Data spacing and
distribution
www.emunl.com.au
info@emunl.com.au
abundance should never be considered a proxy or
substitute for laboratory analysis. Laboratory assay
results are required to determine the widths and
grade of the visible mineralisation (if reported) in
preliminary geological logging.
If core, whether cut or sawn and whether
quarter, half or all core taken.
If non-core, whether riffled, tube sampled,
rotary split, etc and whether sampled wet
or dry.
For all sample types, the nature, quality and
appropriateness of the sample preparation
technique.
Quality control procedures adopted for all
sub-sampling stages to maximise
representivity of samples.
Measures taken to ensure that the
sampling is representative of the in situ
material collected, including for instance
results for eld duplicate/second-half
sampling.
Whether sample sizes are appropriate to
the grain size of the material being
sampled.
The nature, quality and appropriateness of
the assaying and laboratory procedures
used and whether the technique is
considered partial or total.
For geophysical tools, spectrometers,
handheld XRF instruments, etc, the
parameters used in determining the
analysis including instrument make and
model, reading times, calibrations factors
applied and their derivation, etc.
Nature of quality control procedures
adopted (eg standards, blanks, duplicates,
external laboratory checks) and whether
acceptable levels of accuracy (ie lack of
bias) and precision have been established.
The veri cation of signi cant intersections
by either independent or alternative
company personnel.
The use of twinned holes.
Documentation of primary data, data entry
procedures, data veri cation, data storage
(physical and electronic) protocols.
Discuss any adjustment to assay data.
Accuracy and quality of surveys used to
locate drill holes (collar and down-hole
surveys), trenches, mine workings and
other locations used in Mineral Resource
estimation.
Speci cation of the grid system used.
Quality and adequacy of topographic
control.
Data spacing for reporting of Exploration
Results.
Whether the data spacing and distribution
is suf cient to establish the degree of
geological and grade continuity appropriate
for the Mineral Resource and Ore Reserve
estimation procedure(s) and classi cations
applied.
10 Walker Avenue
WEST PERTH WA 6005
Current sampling includes comprehensive and
industry standard QAQC inclusive of split and
duplicate samples, and applicable and representative
standards for copper and gold.
pXRF Analysis
pXRF analysis of soil samples is deemed t for purpose
as a preliminary exploration screening technique.
pXRF provides a spot reading on sample locations with
variable grain sizes and states of homogenisation. High
grade results were repeated at multiple locations to
con rm repeatability. The competent person
considers this acceptable within the context of
reporting preliminary exploration results.
pXRF screening of soil sample points by preliminary
analysis was obtained with a Niton XL5 portable XRF.
‒
NOTE 1: pXRF (portable x-ray fluorescence)
assay results are semi-quantitative only.
‒
NOTE 2: pXRF – Only a selection of path nder
elements are analysed with pXRF analyser:
Cu, As, (add other elements of interest)
Elements detected by pXRF at ppm levels include:
Ag, As, Au, Ba, Bi, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga,
Hf, K, K , La, Mn, Mo, Nb, Nd, Ni
Analytical QC is monitored by the laboratory using
standards, blanks and repeat assays.
Independent standards were submitted by the
Company at a rate of 1:25 samples.
Independent eld duplicates were included at regular
intervals.
Sample locations were captured using a handheld
Garmin RINO GPS using the UTM coordinate system,
with an accuracy of +/- 5m
Map coordinates: all recorded in MGA94, Zone 54
GDA
Sample spacing is suitable for reporting of
exploration results.
Sample spacing is not suitable for Mineral Resource
estimation.
Soil surveys were undertaken on a typical spacing of
20 x 80m in the interpreted mineralised shear zone
areas and up to 100 x 200m in semi-regional
ASX Code: EMU
ABN: 50 127 291 927
17
Criteria
JORC Code explanation
Orientation of data
in relation to
geological
structure
Sample security
Whether sample compositing has been
applied.
Whether the orientation of sampling
achieves unbiased sampling of possible
structures and the extent to which this is
known, considering the deposit type.
If the relationship between the drilling
orientation and the orientation of key
mineralised structures is considered to
have introduced a sampling bias, this
should be assessed and reported if
material.
The measures taken to ensure sample
security.
Commentary
investigations.
Audits or reviews
The results of any audits or reviews of
sampling techniques and data.
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
Soil sampling was undertaken at a perpendicular
angle to the targeted lithological unit.
Sampling is regarded to be unbiased with respect to
the orientation of the lithologies.
Samples are given individual samples numbers for
tracking. The sample chain of custody is overseen by
the Company’s Exploration Manager. Samples were
transported in secure sealed bags to the laboratory.
Sample security and integrity is in place to industry
standards
The sampling techniques and analytical data are
monitored by the Company’s geologists and IT
consultants.
External audits of the data have not been completed.
ASX Code: EMU
ABN: 50 127 291 927
18
Section 2 Reporting of Exploration Results
(Criteria listed in the preceding section also apply to this section.)
Criteria
JORC Code explanation
Commentary
Mineral tenement
and land tenure
status
Exploration done
by other parties
Type, reference name/number, location and
ownership including agreements or material
issues with third parties such as joint ventures,
partnerships, overriding royalties, native title
interests, historical sites, wilderness or national
park and environmental settings.
The security of the tenure held at the time of
reporting along with any known impediments
to obtaining a licence to operate in the area.
Acknowledgment and appraisal of exploration
by other parties.
The tenure hosting the Georgetown Project in this
news release is owned 100% by Rugby Resources
Ltd. EMU NL has the right to earn up to 80%
interest in three EPM’s under a Heads of
Agreement and JVA with Rugby Resources Ltd.
The three EPM’s are:
27642
27664; and
27667
All works undertaken and reported in this ASX
announcement were completed within these
tenements.
The project tenements are all in good standing.
Historical prospecting, sampling and drilling
activities have been undertaken in different areas
within the project tenements intermittently by
multiple third parties over a period of at least 50
years.
Historic RC drilling at Camp-oven Creek and Turtle
Creek was undertaken by Georgetown Mining Pty
Ltd. Historic RC drilling at Munitions Creek was
undertaken by Diatreme Resources Ltd.
Intrusive related epithermal vein system
mineralisation and Cu-Mo Porphyry-style
mineralisation.
Geology
Deposit type, geological setting and style of
mineralisation.
Drill hole
Information
A summary of all information material to the
understanding of the exploration results
including a tabulation of the following
information for all Material drill holes:
o easting and northing of the drill hole collar
o elevation or RL (Reduced Level –
elevation above sea level in metres) of the
drill hole collar
o dip and azimuth of the hole
o down hole length and interception depth
o hole length.
If the exclusion of this information is justi ed
on the basis that the information is not Material
and this exclusion does not detract from the
understanding of the report, the Competent
Person should clearly explain why this is the
case.
In reporting Exploration Results, weighting
averaging techniques, maximum and/or
minimum grade truncations (eg cutting of high
grades) and cut-off grades are usually Material
and should be stated.
Where aggregate intercepts incorporate short
lengths of high grade results and longer
lengths of low grade results, the procedure
used for such aggregation should be stated
and some typical examples of such
aggregations should be shown in detail.
The assumptions used for any reporting of
metal equivalent values should be clearly
stated.
These relationships are particularly important
in the reporting of Exploration Results.
If the geometry of the mineralisation with
respect to the drill hole angle is known, its
No drilling done.
No weighting techniques or grade truncation has
been applied to results.
Results rounded to nearest ppm.
No drilling done.
Data aggregation
methods
Relationship
between
mineralisation
www.emunl.com.au
info@emunl.com.au
10 Walker Avenue
WEST PERTH WA 6005
ASX Code: EMU
ABN: 50 127 291 927
19
Criteria
JORC Code explanation
widths and
intercept lengths
Diagrams
Balanced
reporting
Other substantive
exploration data
Further work
www.emunl.com.au
info@emunl.com.au
nature should be reported.
If it is not known and only the down hole
lengths are reported, there should be a clear
statement to this effect (eg ‘down hole length,
true width not known’).
Appropriate maps and sections (with scales)
and tabulations of intercepts should be
included for any signi cant discovery being
reported These should include, but not be
limited to a plan view of drill hole collar
locations and appropriate sectional views.
Where comprehensive reporting of all
Exploration Results is not practicable,
representative reporting of both low and high
grades and/or widths should be practiced to
avoid misleading reporting of Exploration
Results.
Other exploration data, if meaningful and
material, should be reported including (but not
limited to): geological observations;
geophysical survey results; geochemical
survey results; bulk samples – size and
method of treatment; metallurgical test results;
bulk density, groundwater, geotechnical and
rock characteristics; potential deleterious or
contaminating substances.
The nature and scale of planned further work
(eg tests for lateral extensions or depth
extensions or large-scale step-out drilling).
Diagrams clearly highlighting the areas of
possible extensions, including the main
geological interpretations and future drilling
areas, provided this information is not
commercially sensitive.
10 Walker Avenue
WEST PERTH WA 6005
Commentary
Refer to gures in this announcement with sections
and map plans created using QGIS software.
Refer to maps and gures in body of the
announcement.
Geological interpretations are based on current
knowledge and will change with further exploration.
No inference to economic mineralisation has been
stated.
Key ndings and location information has been
reported in body of text.
Reporting is considered balanced.
All of the relevant data has been included in this
report.
Geological interpretations have been taken from
published maps, geophysical interpretation,
historical and ongoing exploration.
On-going eld recon
Share your feedback